- Owner
- Manatee County Port Authority
- Engineer
- CH2M Hill
- General Contractor
- Spectrum Underground
- Jacking Sub Contractor
- Huxted Tunneling
- Pipe Size
150’ of 66” OD x 1.000 wall & 150’ of 60” OD x .750 wall Permalok® Steel Casing Pipe
The Problem
Microtunneling two drives 150’ each 20’ deep in silty sand and ground water
The Solution
Using a 67” & 61” Iseki Unclemole machine to install the Permalok® Steel Casing pipe, the job was completed on time and on grade with no down time due to welding of the joints.